Products
Contact Us
- Contact Person : Mr. Samantha Du
- Company Name : Shenyang Pusm Medical Device Co., Ltd
- Tel : 86-24-82914480
- Fax : 86-24-89712471
- Address : Liaoning,Shenyang,No 4 Jianshenan Roud, Hushitai Economic And Techonological Zone,Shenyang North New District,Shenyang City,Liaoning Province,China
- Country/Region : China
- Zip : 110122
Surgical Instrument For Hip And Joint Operation Large Torque High Precision Slow Acetabulum Reaming Drill Bone Drill
Product Detailed
Related Categories:Agricultural Product Stock
Surgical instrument for hip and joint operation large torque high precision slow acetabulum reaming drill bone drillApplicationSuitable for all kinds of operation on bone joint.Mainly used in grinding bone tissue.Because of it’s large torque and positioning accuracy can be connected by any brand acetabular grinder and medullary cavity reamer.SpecificationDiameter of drill chuck0-8mmInput voltage110V-240V/50HzBattery capacity1800mA/hRated speed≥120rpmRating torque13NmCharging voltage14.4VSterilizationHTHPSterilizing temperature134°C-138°CNoise≤60dbStandard Configuration1. One handpiece 2. Two batteries3. One charger4. One aseptic battery transfer ring5. One operating manual6. One guarantee card 7. One certificateWarranty: Handpiece warranty is 12 months and lifetime maintenance. Battery warranty is 3 months.Advantages:1.Integrated Design 1.1.With this design, the bone drill and saw have excellent sealing.Therefore, when the device is sterilized, the motor will be damaged less. 1.2.With this design, the decomposition of vibration is strong ,so that the noise is very small.2.Ergonomic Design, Feel Comfortable In the design, the weight of top and bottom are almost same, so it is avoid hand fatigue when using the product.3.Large Battery Capacity The battery capacity is larger than similar products in the market to make the power to satisfy the customers' needs.4.Imported Motor It can increase operation efficiency and precision.Notes1、Before the operation,the bone drill must be sterilized according to the sterilization.Battery and charger must not be sterilized.2、Before the operation,the battery must be filled,and the filled battery must be cooled and then put into the handpiece.3、After use,must to be cleaned,then remove the battery.And don’t put the battery and the handpiece together.Do not drop impact , to damage the battery. 4、Don’t put the battery in the place where the temperature is higher than 40℃5、If there is abnormal phenomena during the operation,stop using it.6、Prohibited in flammable, explosive materials nearby7、If don’t use for long time, the battery should be regularly charged to ensure the battery life.
Other products