Products
Contact Us
- Contact Person : Mr. Samantha Du
- Company Name : Shenyang Pusm Medical Device Co., Ltd
- Tel : 86-24-82914480
- Fax : 86-24-89712471
- Address : Liaoning,Shenyang,No 4 Jianshenan Roud, Hushitai Economic And Techonological Zone,Shenyang North New District,Shenyang City,Liaoning Province,China
- Country/Region : China
- Zip : 110122
New Design Autoclavable Dual Function Sterilize For Intramedullary Nail And Kirschner Wire Operation Trauma Surgery Drill
Product Detailed
Related Categories:Agricultural Product Stock
New design autoclavable dual function sterilize for intramedullary nail and kirschner wire operation trauma surgery drillApplicationSuitable for all kinds of brands of intramedullary nail and the kirschner wire operation.Center hole diameter is 4.0mm. Because of precise concentricity , especially spindle hole directly,improve the accurancy of operation and make the operation more perfect.SpecificationDiameter of drill chuck0-8mmInput voltage110V-240V/50HzOutput power≥70WBattery capacity2500mA/hRated speed ≧1000rmp Rating torque6.3NmCharging voltage14.4VSterilizationHTHPSterilizing temperature134°C-138℃Noise≤60dbStandard Configuration1. One handpiece 2. Two batteries3. One charger4. One aseptic battery transfer ring5. One operating manual6. One guarantee card 7. One certificateWarranty:The handpiece guarantees for 1 years, the battery a guarantee for 3 months.Advantages:1.Integrated Design 1.1.With this design, the bone drill and saw have excellent sealing.Therefore, when the device is sterilizted, the motor will be damaged less. 1.2.With this design, the decomposition of vibration is strong ,so that the noise is very small.2.Ergonomic Design, Feel Comfortable In the design, the weight of top and bottom is almostly same, so it is avoid hand fatigue when using the product.3.Large Battery Capacity The battery capacity is larger than similar products in the market to make the power to satisfy the customers' needs.4.Imported Motor It can increase operation efficiency and precision.Notes1、Before the operation,the bone drill must be sterilized according to the sterilization.Battery and charger must not be sterilized.2、Before the operation,the battery must be filled,and the filled battery must be cooled and then put into the handpiece.3、After use,must to be cleaned,then remove the battery.And don’t put the battery and the handpiece together.Do not drop impact , to damage the battery. 4、Don’t put the battery in the place where the temperature is higher than 40℃5、If there is abnormal phenomena during the operation,stop using it.6、Prohibited in flammable, explosive materials nearby7、If don’t use for long time, the battery should be regularly charged to ensure the battery life.
Other products